Power budget for the backbone
NMEA 2000 network load calculator
Add up the Load Equivalency Number (LEN) of each device on your NMEA 2000 network and compare the estimated current with the rating of the supply you enter. Everything is worked out in your browser from the numbers you type; this page holds no device data.
Estimate
Add at least one device's LEN to see an estimate.
- Total LEN
- 0
- Estimated current
- 0 mA
- Share of the rating
How the estimate is worked out
Estimated current (mA) = (LEN1 × qty1 + LEN2 × qty2 + …) × 50 mA
Estimated current (A) = estimated current (mA) ÷ 1,000
Share of the rating (%) = estimated current (A) ÷ supply rating (A) × 100
Assumptions
- One LEN stands for 50 mA of current drawn from the network, as defined for NMEA 2000 networks (see Garmin's NMEA 2000 Glossary, Garmin).
- The comparison is for one powered segment at a time, using the output current available to that segment. It cannot check voltage drop, cable or power-feed limits.
- Calculator input limits: 1,000 LEN per row, 500 devices per row, a 1,000 A rating and 40 rows. These are limits of this page, not of the standard.
- Each LEN comes from the device's own label or documentation. A blank quantity counts as one.
- No allowance is made for voltage drop along the cable, the cable type or length, or where the power is connected. Those need the cable and power documentation for your network.
- The result is an estimate to plan with, not a measurement of your boat.
Terminators
An NMEA 2000 backbone has a 120 Ω terminator at each physical end, whatever the load (see the same Garmin glossary).